TEMA Type ‘AEW’ HEAT EXCHANGERS
|
| and |
| LUBE OIL COOLERS |
| MEETING THE REQUIREMENTS OF API 614 , AP1 617 & AP1 618 |
| In Single Pas or Two Pass Design |
| For APPLICATION In |
| |
| |
LUBE OIL COOLING
JACKET WATER
STEAM / GAS TURBINE OIL
HYDRAULIC OIL
|
CONDENSATE COOLING
COMPRESSED AIR
BEARING JACKET
MARINE APPLICATION
|
|
|
 |
| |
CONSTRUCTION FEATURES INCLUDE REMOVABLE TUBE BUNDLES-, OPTIONAL
NOZZLE LOCATION , REMOVAL OF BONNET WITHOUT DISTURBING THE PIPING ,
NO NEED TO EMPTY THE SHELL SIDE FOR INSPECTION or CLEANING . VITON “O” RING
WITH ITS SPECIAL RETAINER RING MAKES INSPECTION AND CLEANING OF TUBES
VERY EASY. EXTERNAL SURFACES SAND BLASTED AND ENAMEL/EPOXY PAINTED |
| |
| |
AVAILABLE MATERIAL OF CONSTRUCTION: |
| |
|
|
|
| |
SHELL TUBES
Bare or Lowfin
TUBE SHEETS
CHANNELS |
CS. Stainless Steel
CS. Stainless steel ,Copper
Admiralty , 90/10 & 70/10 CuNi
Titanium (bare or Lowfin)
CS, Stainless Steel , Naval Brass
CuNi , Titanium
CS , Stainless Steel ,CI |
|
|
| |
| |
Standard Size designed for 10.5 Kg / Cm2, (150 Psi)@ 150 ° C in 4, 5 ,6 ,8,10,12“ NB Thermal Design fecilities with HTRI software. Each Exchanger pneumatic & Hydraulic pressure Tested. Supply at short delivery periods
|
|
|
| |
|
|